SPT series inveter charger Features
Auto switch 4 FUN: DC to AC, AC bypass, AC charger, and UPS
Start Auto restart while AC is recovering, Dry contact: out no AC signal to another device
Pure sine wave output, input & output fully isolation Three-gear switch
Includes 4-stage AC battery charger, charging current up to 90A
Efficiency can reach above 88%, energy saving mode, extend the working hours of battery
Can be paired with electric, diesel hybrid power supply
Tolerance3 times rated power to start, the carrying capacity of excellence
Advanced microprocessor control system design
Input polarity/UV/OV/OS/OL/OT protections
Remote control RJ45 or RS-232 communication interface (optional)
Models |
SPT4000-124 |
SPT4000-148 |
SPT4000-224 |
SPT4000-248 |
Output Power |
4000W |
|||
Surge Power |
12000W |
|||
DC Input Voltage |
24VDC |
48VDC |
24VDC |
48VDC |
Output Voltage |
100/110/120VAC±5% |
220/230/240VAC±3% |
||
Output Frequency |
50/60Hz ±0.5% |
|||
Output Waveform |
True sine wave(THD<5%) |
|||
Power Factor |
0.1~1 |
|||
Efficiency |
86% |
88% |
87% |
90% |
No Load Power |
<10W(Power saving mode) |
|||
Transfer Time |
<8 ms |
|||
AC Range |
90~135VAC/190~245VAC |
|||
Voltage Range |
10.0~16.0VDC |
20.0~31.0VDC |
10.0~16.0VDC |
20.0~31.0VDC |
Charge Current |
50A |
30A |
65A |
35A |
Fault Indication |
LED Red |
|||
Remote Control |
RJ11 |
|||
Safety |
UL458 |
LVD(EN60950) |
||
EMC |
FCC Part15 ClassA |
CE (EN55022:2006+A1:2007) |
||
Operating Temp |
-20~50℃ |
|||
Working Humidity |
20~90%RH |
|||
Storage Temp |
-30~70℃ |
|||
Cooling |
Automatically controlled cooling fan |
|||
Weight (kg) |
35 |
|||
Size (mm) |
600*218*180 (L*W*H) |
|||
Application |
The vehicle, Yacht, Solar power systems, Portable equipment, Power tools, Home and Office appliances |
rv electrical system schematic
Pictures of Installation :
Contact: Hayden
Phone:
Tel: 0512-68638910
Email: hayden@cosuper.com
Add: Rm. 103, Bldg. 18.No. 99, Gangtian Road